Highly flexible cable for dry areas, used for connection of small mobile devices, requiring special flexibility in conditions free of any mechanical stresses. Permitted frequent bending, but no twisting. Suitable for radios, desk lamps, electric razors and similar household or office devices, as long as the cable is adapted to essential specifications of the device. Not suitable for cookers and hot devices. Fixed cable connection to the device or by means of a small plug. Cable ends must be provided with inseparable plugs additionally protected by rubber or thermoplastic insertion. Cable length must not exceed 2 m.

Flexible, max conducture temperature 40, Min installation temperature -5
specs
Constructional Wires
Electrical Specs:
Code NR | conductor cross-section | Construction of individual conductor | Outer dimension | Insulation thickness | Conductor resistance at 20 °C | Cable weight | Packing* |
nominal | min-max. | nominal | max | approx. | |||
mm² | n x mm | mm | mm | Ω/km | kg/km | ||
10250 | 0.5 | 16x0,19 | 2.6x5.2 | 0.8 | 39 | 22 | c.100, c.200 |
10275 | 0.75 | 24x0,195 | 2.8x5.6 | 0.8 | 26 | 28 | c.100, c.200 |
*)Packing: c.100 = coil 100 m, c.200 = coil 200 m CUT= cable in different lengths on drum or reel, possible cutting at required |
Physical Specs:
Conductor: | bare copper conductor, class 5 acc. to IEC 60228 / HD 383 / DIN VDE 0295 | |
Insulation: | PVC compound TI2 acc. to DIN VDE 0207 4. part / HD 21.1 S4, flat shaped insulation with both-sides central groove for easy separation of conductors |
Technical Specs:
Temperature during installationi: | +5 °C up to +40 °C |
Temperature at short circuit of max. 5 s: | up to 150 °C |
Nominal voltage: | Uο/U = 300/500 V |
Test Voltage | 2000 V |
Minimal inner bending radius: | 5D |
Behaviour in fire: | IEC 60332-1 |